Number 1, The oily substance is Soap suds that I have used for years that I learned to use in college, if I still have a leak I will pull out my and use my electronic leak detector made by BacarackThe problem they have is they have under designed line set that was for the old system which was 1/for the discharge line and 5/for the suction lineAll discharge lines are warm to touchThis line was cold to touch which I felt the refrigerant was backing up into the condenserI told Mr C [redacted] this and I was screamed by his wife that their old unit worked fine on on the old systemThey never listened to meThe new system requires a 3/and a 3/line set and I can prove this from the manufacture literature and from piping chartsMr C [redacted] has not returned my phone calls or my text messagesThe last time I talked to First American they were pay for a a better contractor to go over my workLOL I know every contractor in this area, and they would be shocked if I told them what was going on with me

Number 1, The oily substance is Soap suds that I have used for years that I learned to use in college, if I still have a leak I will pull out my and use my electronic leak detector made by BacarackThe problem they have is they have under designed line set that was for the old
system which was 1/for the discharge line and 5/for the suction lineAll discharge lines are warm to touchThis line was cold to touch which I felt the refrigerant was backing up into the condenserI told Mr C*** this and I was screamed by his wife that their old unit worked fine on on the old systemThey never listened to meThe new system requires a 3/and a 3/line set and I can prove this from the manufacture literature and from piping chartsMr C*** has not returned my phone calls or my text messagesThe last time I talked to First American they were pay for a a better contractor to go over my workLOL I know every contractor in this area, and they would be shocked if I told them what was going on with me

Number 1, The oily substance is Soap suds that I have used for 45 years that I learned to use in college, if I still have a leak I will pull out my and use my electronic leak detector made by Bacarack. The problem they have is they have under designed line set that was for the old system which...

was 1/4 for the discharge line and 5/8 for the suction line. All discharge lines are warm to touch. This line was cold to touch which I felt the refrigerant was backing up into the condenser. I told Mr C[redacted] this and I was screamed by his wife that their old unit worked fine on on the old system. They never listened to me. The new system requires a 3/8 and a 3/4 line set and I can prove this from the manufacture literature and from piping charts. Mr C[redacted] has not returned my phone calls or my text messages. The last time I talked to First American they were pay for a a better contractor to go over my work. LOL I know every contractor in this area, and they would be shocked if I told them what was going on with me.

Check fields!

Write a review of Coastal Air

Satisfaction rating
 
 
 
 
 
Upload here Increase visibility and credibility of your review by
adding a photo
Submit your review

Coastal Air Rating

Overall satisfaction rating

Address: *, San Luis Obispo, California, United States, 93405

Phone:

Show more...

Add contact information for Coastal Air

Add new contacts
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | New | Updated