We have already responded thanks

I have pictures of the wires from the tech they where cut with the weed whacker after the new install which was not are fault if u have any concerns call the Managment company please thank u

I will have to send several emails to get you all the pictures and the invoices from the company I had to hire to fix the problems [redacted] INVOICEBILL TO [redacted] **[redacted] ***INVOICE # ***DATE 07/07/2016DUE DATE 07/07/2016TERMS Due on receiptACTIVITY AMOUNTHVAC Equipment RepairHVAC Equipment RepairTechnician repair/services done to HVAC equipment.Scope of Work:No AC/AC wires shocked son-in-law while he was cleaning behind the condenserThe T-Stat wires were shorted to themselves due to the wire being bareThe 24v wires have beenrepaired by cutting the wire back to a spot where there was still insulationRemoving all the badwiring all the way into the condenserThen adding about 2.5ft of new 18/24v CommWire fromthe new barrel connected splice back to the condenser 24v coil hookupsNext the existingrefrigerant lines had insulation around them at one time but the sun has aged the insulation to thepoint of it being brittle and flaking offSomeone tried to cover this with non-approved tape that isnot UV or UL listedThe tape and bad insulation was removedNew 1/2" synthetic approved foaminsulation was added as well as the appropriate UV and UL listed tape was used to cover therefrigerant lines and also secure the thermostat wires as approved by state and national codes.(See attached pictures)Finally the condenser fuses were replaced along with the 24v 5a fusedlink in the furnace.127.50HVAC MiscJob MaterialsMaterials Used To Complete An HVAC Related Project2.5ft - 18/CommWire2.0ft - 1/2" Black Armour-Flex Foam Insulation- Roll UL Listed Black Tape- 25a Slow-Blow Emergency Disconnect Fuses1- 5a SS Filament Fuse67.00ACTIVITY AMOUNTSuggestionsSuggestions, Recommended Services or Technician AdviceThis circuit is only 24v but it can be potentially dangerousThe installing company of the newcooling system made a few potentially dangerous and potentially harmful mistakes to both humansand the new equipmentUnfortunately, due to their ignorance the warranty on the new Carrierequipment is voidedWhen I called and explained the situation to Carrier they made notes that theequipment would be label invalid due to the mistakes made by the installing companyI wassimply asking for the best way to rectify the mistakes made so the warranty could be retained andthey explained that the mistakes could have been rectified BEFORE the units were activated butnot afterThus the evaporator coil and condenser are no longer covered by their warrantyI have alist of issues that need to be resolvedIf it is warrantedAlso this system was not inspected eitherand the city is now aware of that as wellAgain trying to acquire information on the installingcompany that issue became known by myself and the city of MiddletonI feel ultimately theinstalling company is now in debt to the management companyThe actions here areunacceptable and need to be further investigated then resolved to prevent further equipmentfailure and the possibility of reacquiring the 7yr Carrier warranty.0.00This invoice is for the unit located at [redacted] BALANCE DUE $

Complaint: [redacted] I am rejecting this response because:I have pictures from the tech I hired to fix the problem and his statement saying that those wires were very brittle from extended exposure to weather and should have been replaced and wrapped properly when the new unit was installed I can give you the name and number of the tech I hired stating it was not my fault and there was no week whacker used behind the unit as none would fit The wires and hoses were not replaced like they should have been that is what caused the shorting out of the unit.Sincerely, [redacted]

We restored water to her house and found it was irrigation leaking and home owner had no coverage for thatWe restored water within days here crawl space was full of water all the way to the opening there was no way for us to restore water till the restoration company could get it pumped out and partially dry out

Check fields!

Write a review of Knight Plumbing and Construction

Satisfaction rating
 
 
 
 
 
Upload here Increase visibility and credibility of your review by
adding a photo
Submit your review

Knight Plumbing and Construction Rating

Overall satisfaction rating

Add contact information for Knight Plumbing and Construction

Add new contacts
A | B | C | D | E | F | G | H | I | J | K | L | M | N | O | P | Q | R | S | T | U | V | W | X | Y | Z | New | Updated